National Highway Traffic Safety Administration2017 Keystone FuzionElectrical

Electrical wiring in the under belly of the rv is routed and pinched between the frame crossmembers and wastewater holding tank

ODI Happened May 3, 2019Filed May 9, 2019

In the owner's words

Electrical wiring in the under belly of the rv is routed and pinched between the frame crossmembers and wastewater holding tank. This creates fraying of the the electrical wire covering which is resulting in the wires being broken and result in fire or electrical shock. Wiring should be ran in a manner where it is protected from being pinched and/or wearing on metal crossmembers.*dt *dt*jb consumer stated keystone wanted the consumer to bring it in for wiring inspection.*jb *dt*dt*jb